TM
Specifications
Communications
Serial Interface Ports:
– SCRAMBLE*NET: Requires SNIB.
Encrypted message structure.
– RS-485 multi-drop or RS-232
protocol
– Optically isolated serial port
– Baud Rate: 9600 or 19,200
– RS-485: 4000 ft. (1220m) with 22
gauge. 2 pair, stranded, twisted,
overall shield
– RS232: 50 ft (15m) @9600 baud
Parallel Printer Port: Standard
Keypad/Reader Port: 16 device
addresses
– Any address for command and
programming
– Wiring: 750 ft (160m) with 22
gauge, 1800 ft (550m) with 18
gauge. 2 pair, stranded, twisted,
overall shield.
Firmware
Command & Control Module (CCM):
– Removable & Upgradable
– Time Zones: 150
– Access Zones: 128
– Control Zones: 256
– Holidays: Four 366 Day x 2 years
– Daylight Savings Time Adjustment
Dial-Up to Remote Host:
– Phone Numbers: 4, with roll over
– User selectable retry attempts
– Call-back mode for security
– Initiation by alarm, buffer % full,
and/or time
Memory
Buffers: 1500 events, 1500 alarms
standard
– 20,000 events, 2,000 alarms with
MEB/BE
– 20,000 events, 2,000 alarms with
MEB/CB (reduces users by 20%)
– Oldest discarded first, if full
Users: 4000 standard
– 8000 with MEB/CE16
– 20,000 with MEB/CE 32
– 68,000 with MEB/CB64
– 132,000 with MEB/CB128
Battery Backup: 30 day for code,
setups, clock and buffer
Electrical
Keypad/Reader Power: 2 terminals
– 1.0 Amp @24VDC each, fused
– 1.15 Amp @24VDC, total
– Powers ScramblePad,
ScrambleProx and MATCH
Primary and Standby Power:
– 90-130VAC, 50/60 Hz, fused
– 180-260VAC, 50/60 Hz, fused
Uninterruptible Power Supply
Standby Batteries: 1.3 AH Included
Control Relays: 2 Amp, Form C
(requires REB8)
Alarm Relays: 2 Amp, Form C
LEDs:
– Individual Relay Status
– Battery (OK, Low, Fail)
– AC (OK, Fail)
– System (OK, Fail)
– Keypad/MATCH (Poll, Response)
– SCRAMBLE*NET (Poll, Response)
– Test Mode
– Alarm Events in Buffer
– Box Tamper Alarm
Physical
Door Tamper Switch
Medeco High Security Key Lock
Enclosure: NEMA type, with con-
duit knockouts & removable door
Dimensions: 18”H x 15.25”W x 5.5”D
(45.7cm x 38.7cm x 14cm)
Expansion Boards:
6”H x 4.25” W x .75”D
(15.2cm x 10.8cm x 1.9cm)
Shipping Weight: 30lbs (13.6kg)
Expansion Boards: 1 lb (.5kg)
Operating Temperature Range: 32°F
to 140°F (0° to 60°C)
Relative Humidity: 0 to 90%,
non-condensing
Listing & Approvals
UL 1076 Proprietary Burglar Alarm
Systems, Grade AA
CE
DTLM1
SCRAMBLEPAD
OR
SCRAMBLEPROX
FUSE
G+ABS S LOHI
G
+
A
B
S
DIGI*TRAC
Typical Controller-to-Alarm Point Wiring Diagram.
KEYPAD
TERMINAL
BLOCK
INPUT
TERMINAL
BLOCK
Comentarios a estos manuales