Ordering Information –– Controller
Model #
M16N
Description
DIGI*TRAC MODEL
16N - 16 Input
Comments
16 Input Controller. 4000 Users. Includes 16 Alarm Inputs (requires
Line Modules), enclosure, power supply, battery, tamper switch,
Medeco lock and SNIB. Supports Expansion Boards (NO AEB8
with SNAP, SAM, or MOMENTUM). CE. UL Listed. 115VAC.
Model #
AEB8
REB8
MEB/BE
MEB/CE16
MEB/CB64
MEB/CB128
DM9600A-DL
Description
Alarm Expansion Board - 8 Inputs
Relay Expansion Board - 8 Relays
Memory Expansion Board - Buffer
Expansion
Memory Expansion Board -
CODE Expansion 4,000/16,000
Memory Expansion Board -
CODE Expansion of 64,000 with
Buffer Option
Memory Expansion Board -
CODE Expansion of 128,000 with
Buffer Option
DIGI*TRAC 9600 BAUD
MODEM ASSEMBLY
(Factory Set: Dial-Up Line)
Comments
Adds 8 additional high security alarm inputs. SNAP, SAM and
MOMENTUM support up to 2 boards in M2, M8, MSP or M64.
Velocity supports up to 4 boards in M2, M8, MSP, M64 and up to 2
boards in M16. Each input requires appropriate Line Module.
Features removable connectors. UL Listed. CE.
Adds 8 additional 2 Amp Form C relays to an M2, M8, M16 or
MSP-8R. May not be installed in an M64. A total of 5 (4 if net-
worked) REB8 Boards may be installed in all other DIGI*TRAC con-
trollers. Removable connectors & status LEDs. UL Listed. CE.
Expands standard buffer from 1500 events and 1500 alarms to
20,000 events and 2,000 alarms with CCM 7.X. Expands standard
buffer from 37 events and 37 alarms (700 events and 700 alarms with
CE boards) to 20,000 events and 2,000 alarms with CCM 6.6.
Protected from data loss during power failures for up to 30 days by
controller memory battery. UL Listed. CE.
Expands CODE Memory from 4,000 to 8,000 on Velocity and
MOMENTUM with CCM 7.X. Not recognized by SNAP or SAM
with CCM 7.X. Expands CODE Memory from 1,000 to 16,000 max-
imum with CCM6.X. Protected from data loss during power failures
for up to 30 days by controller memory battery. UL Listed. CE.
Expands CODE Memory by 64,000 (from 4,000 to 68,000) with
CM 7.X on Velocity and MOMENTUM. Not recognized by CCM 6.6
or earlier. A portion of the Code Memory may be allocated to alarm
and event Buffers on Velocity only. Protected from data loss during
power failures for up to 30 days by controller memory battery. CE.
UL Listed.
Expands CODE Memory by 128,000 (from 4000 to 132,000) with
CCM 7.X on Velocity and MOMENTUM. Not recognized by CCM
6.6 or earlier. A portion of the Code Memory may be allocated to
alarm and event Buffers on Velocity only. Protected from data loss
during power failures for up to 30 days by controller memory battery.
CE. UL Listed.
A miniature 9600 Baud Modem Assembly that can be powered from
& installed internally in the M1, M2, M8, M16 or MSP for remote site
management via dial-up network. Includes cables, adaptor, & power
supply harness. Do not use at Host PC or NET*MUX4 outport.
Ordering Information –– Expansion Boards & Modem
Note: The DIGI*TRAC M16 Controller can accommodate up to 5 expansion boards. Only one MEB/CE or MEB/CB is supported per
controller. A maximum of 2 AEB8 expansion boards are supported in the M16 (only with CCM7.x or later and Velocity).
TM
Systems With Integrity
Specifications are subject to change without notice.
Global Headquarters
1900 Carnegie Ave., Bldg. B, Santa Ana, CA 92705 USA
949-250-8888 Fax 949-250-7372
www.HirschElectronics.com
PDS006-203
Note: Add “-230” to model numbers for 230 VAC.
Comentarios a estos manuales